一、POE供電簡介
POE (Power Over Ethernet)指的是在現(xiàn)有的以太網(wǎng)Cat.5布線基礎(chǔ)架構(gòu)不作任何改動(dòng)的情況下,在為一些基于IP的終端(如IP電話機(jī)、無線局域網(wǎng)接入點(diǎn)AP、網(wǎng)絡(luò)攝像機(jī)等)傳輸數(shù)據(jù)信號(hào)的同時(shí),還能為此類設(shè)備提供直流供電的技術(shù)。 POE也被稱為基于局域網(wǎng)的供電系統(tǒng)(POL, Power over LAN )或有源以太網(wǎng)( Active Ethernet),有時(shí)也被簡稱為以太網(wǎng)供電,這是利用現(xiàn)存標(biāo)準(zhǔn)以太網(wǎng)傳輸電纜的同時(shí)傳送數(shù)據(jù)和電功率的最新標(biāo)準(zhǔn)規(guī)范,并保持了與現(xiàn)存以太網(wǎng)系統(tǒng)和用戶的兼容性。
二、POE特點(diǎn)
POE技術(shù)能在確保現(xiàn)有結(jié)構(gòu)化布線安全的同時(shí)保證現(xiàn)有網(wǎng)絡(luò)的正常運(yùn)作,最大限度地降低成本。IEEE 802.3af標(biāo)準(zhǔn)是基于以太網(wǎng)供電系統(tǒng)POE的新標(biāo)準(zhǔn),它在IEEE 802.3的基礎(chǔ)上增加了通過網(wǎng)線直接供電的相關(guān)標(biāo)準(zhǔn),是現(xiàn)有以太網(wǎng)標(biāo)準(zhǔn)的擴(kuò)展,也是第一個(gè)關(guān)于電源分配的國際標(biāo)準(zhǔn)。
三、POE的系統(tǒng)構(gòu)成
poe供電一個(gè)完整的POE系統(tǒng)包括供電端設(shè)備(PSE, Power Sourcing Equipment)和受電端設(shè)備(PD, Powered Device)兩部分。PSE設(shè)備是為以太網(wǎng)客戶端設(shè)備供電的設(shè)備,同時(shí)也是整個(gè)POE以太網(wǎng)供電過程的管理者。而PD設(shè)備是接受供電的PSE負(fù)載,即POE系統(tǒng)的客戶端設(shè)備,如IP電話、網(wǎng)絡(luò)安全攝像機(jī)、AP及掌上電腦( PDA)或移動(dòng)電話充電器等許多其他以太網(wǎng)設(shè)備(實(shí)際上,任何功率不超過13W的設(shè)備都可以從RJ45插座獲取相應(yīng)的電力)。兩者基于IEEE 802.3af標(biāo)準(zhǔn)建立有關(guān)受電端設(shè)備PD的連接情況、設(shè)備類型、功耗級(jí)別等方面的信息聯(lián)系,并以此為根據(jù)PSE通過以太網(wǎng)向PD供電。
四、POE供電工作過程
當(dāng)在一個(gè)網(wǎng)絡(luò)中布置 POE供電端設(shè)備時(shí),POE以太網(wǎng)供電工作過程如下所示。
1. 檢測(cè):一開始,POE設(shè)備在端口輸出很小的電壓,直到其檢測(cè)到線纜終端的連接為一個(gè)支持IEEE802.3af標(biāo)準(zhǔn)的受電端設(shè)備。
2.PD端設(shè)備分類:當(dāng)檢測(cè)到受電端設(shè)備PD之后,POE設(shè)備可能會(huì)為PD設(shè)備進(jìn)行分類,并且評(píng)估此PD設(shè)備所需的功率損耗。
3. 開始供電:在一個(gè)可配置時(shí)間(一般小于15μs)的啟動(dòng)期內(nèi),PSE設(shè)備開始從低電壓向PD設(shè)備供電,直至提供48V的直流電源。
4.供電:為PD設(shè)備提供穩(wěn)定可靠48V的直流電,滿足PD設(shè)備不越過 15.4W的功率消耗。
5.斷電:若PD設(shè)備從網(wǎng)絡(luò)上斷開時(shí),PSE就會(huì)快速地(一般在300~400ms之內(nèi))停止為PD設(shè)備供電,并重復(fù)檢測(cè)過程以檢測(cè)線纜的終端是否連接PD設(shè)備。
五、POE供電的原理
標(biāo)準(zhǔn)的五類網(wǎng)線有四對(duì)雙絞線,但是在10M BASE-T和100M BASE-T中只用到其中的兩對(duì)。IEEE80 2.3af允許兩種用法,應(yīng)用空閑腳供電時(shí),4、5腳連接為正極,7、8腳連接為負(fù)極。
應(yīng)用數(shù)據(jù)腳供電時(shí),將DC電源加在傳輸變壓器的中點(diǎn),不影響數(shù)據(jù)的傳輸。在這種方式下線對(duì)1、2和線對(duì)3、6可以為任意極性。
標(biāo)準(zhǔn)不允許同時(shí)應(yīng)用以上兩種情況。電源提供設(shè)備PSE只能提供一種用法,但是電源應(yīng)用設(shè)備PD必須能夠同時(shí)適應(yīng)兩種情況。該標(biāo)準(zhǔn)規(guī)定供電電源通常是48V、13W的。PD設(shè)備提供48V到低電壓的轉(zhuǎn)換是較容易的,但同時(shí)應(yīng)有1500V的絕緣安全電壓。
POE通過電纜供電的原理
標(biāo)準(zhǔn)的五類網(wǎng)線有四對(duì)雙絞線,但是在l0M BASE-T和100M BASE-T中只用到其中的兩對(duì)。
IEEE80 2.3af允許兩種用法如圖1和圖2所示。
圖1 通過空閑腳供電
圖2 通過數(shù)據(jù)腳供電
應(yīng)用空閑腳供電時(shí),4、5腳連接為正極,7、8腳連接為負(fù)極。
應(yīng)用數(shù)據(jù)腳供電時(shí),將DC電源加在傳輸變壓器的中點(diǎn),不影響數(shù)據(jù)的傳輸。在這種方式下線對(duì)1、2和線對(duì)3、6可以為任意極性。
POE的兩種供電方法
POE標(biāo)準(zhǔn)為使用以太網(wǎng)的傳輸電纜輸送直流電到POE兼容的設(shè)備定義了兩種方法:一種稱作“中間跨接法”( Mid -Span ),使用以太網(wǎng)電纜中沒有被使用的空閑線對(duì)來傳輸直流電,相應(yīng)的Endpoint PSE支持POE功能的以太網(wǎng)交換機(jī)、路由器、集線器或其他網(wǎng)絡(luò)交換設(shè)備。另一種方法是“末端跨接法”(End-Span),是在傳輸數(shù)據(jù)所用的芯線上同時(shí)傳輸直流電,其輸電采用與以太網(wǎng)數(shù)據(jù)信號(hào)不同的頻率。Midspan PSE是一個(gè)專門的電源管理設(shè)備,通常和交換機(jī)放在一起。它對(duì)應(yīng)每個(gè)端口有兩個(gè)RJ45插孔,一個(gè)用短線連接至交換機(jī),另一個(gè)連接遠(yuǎn)端設(shè)備??梢灶A(yù)見,End-Span會(huì)迅速得到推廣,這是由于以太網(wǎng)數(shù)據(jù)與輸電采用公用線對(duì),因而省去了需要設(shè)置獨(dú)立輸電的專用線,這對(duì)于僅有8芯的電纜和相配套的標(biāo)準(zhǔn)RJ-45插座意義特別重大。
圖3是POE供電系統(tǒng)的一個(gè)實(shí)例,由供電設(shè)備PSE 、受電設(shè)備PD和相關(guān)的配套設(shè)備及以太網(wǎng)傳輸電纜組成。
圖3 符合IEEE 802.3af標(biāo)準(zhǔn)的以太網(wǎng)供電系統(tǒng)實(shí)例
當(dāng)PD設(shè)備與POE標(biāo)準(zhǔn)兼容時(shí)就可直接通過RJ-45插座從以太網(wǎng)電纜供電,對(duì)于與POE不兼容的設(shè)備可以采用直流變換器或抽頭分壓裝置的方法,將其電壓變換成POE兼容的電壓。這些裝置有時(shí)也被稱為有源以太網(wǎng)分裂器(Sputters),它可以將太網(wǎng)電纜的直流電壓取出來并通過常規(guī)的直流插座供PD設(shè)備使用。
六、IEEE 802.3af與IEEE 802.3at比較
與802.3af相比,802.3at可輸出2倍以上的電力,每個(gè)端口的輸出功率可在30W以上,因此可大幅拓寬PoE的應(yīng)用領(lǐng)域:雙波段接入,視頻電話,802.11接入,RFID接入,工業(yè)傳感器,POS終端等都將可以應(yīng)用PoE技術(shù)來給終端提供充足的電力。
就標(biāo)準(zhǔn)而言,兩者在功率、分級(jí)、線纜上有不同的定義,下表是兩者的比較:
802.3af與802.3at的對(duì)比
在802.3at制定之初,IEEE就目標(biāo)作過表述,以下可以參考:
The 802.3at Task Force objectives are along the following lines:
? 802.3at should operate on CAT5 and higher infrastructure, unlike 802.3af, that had take into account the CAT3 limitations
? 802.3at should follow the power safety rules and limitations pertinent to 802.3af
? A 802.3at PSE must be backwards compatible with 802.3af, being able to power both 802.3af and 802.3at PD‘s
? 802.3at should provide the maximum power to PD’s as allowed within practical limits, at least 30W
? 802.3at PDs, when connected to a legacy 802.3af PSE, will provide the user an indication that a 802.3at PSE is required.
? Research the operation of midspans for 1000BASE-T
? Research the operation of midspans and endspans for 10GBASE-T
七、POE+關(guān)鍵問題
當(dāng)該任務(wù)組開始著手制定一個(gè)更高功率的新標(biāo)準(zhǔn)時(shí),很多人都認(rèn)為這將是一項(xiàng)可在短時(shí)間內(nèi)完成的任務(wù),只需增加電流和電壓而已,至少40W的功率就唾手可得。但是,當(dāng)該任務(wù)組開始探究與較高功率有關(guān)的技術(shù)細(xì)節(jié)時(shí),很多問題出現(xiàn)了,其中有些問題目前仍未解決。
1、電纜載流量與散熱問題
電纜載流量是最基本的問題之一,也最先被提出。而且,對(duì)于這一基本問題,直到近期電纜專家們才給出了答案。像所有電子組件一樣,電纜工作時(shí)也有最高環(huán)境溫度要求,令人關(guān)切的是,電纜過熱可能損壞絕緣材料,從而改變傳輸特性并縮短外部絕緣層的預(yù)期壽命。最近,美國電信行業(yè)協(xié)會(huì)(TIA)發(fā)布了一些初步的指引,建議當(dāng)電纜制造廠每束電纜的根數(shù)被限制為100時(shí),CAT5E可以支持每導(dǎo)線360mA的載流量(所有導(dǎo)體均處于運(yùn)行狀態(tài))。在電纜環(huán)境溫度達(dá)到45℃時(shí),這樣的工作電流是可以接受的,若要在更高的溫度條件下工作,則需要降額。
此外,由于電纜通常被匝成電纜束并置于配線柜中,因此線纜束的散熱問題亦需要考量。
2、數(shù)據(jù)變壓器(Data Transformer)
數(shù)據(jù)變壓器是系統(tǒng)中第二個(gè)真正令人關(guān)切的組件。如大家所知,數(shù)據(jù)變壓器用來將數(shù)據(jù)信號(hào)從PHY交流耦合到電纜中,同時(shí)注入用作PoE電源的直流電流。隨著該變壓器中直流電流的升高,并聯(lián)電源通路中小的電阻不平衡在變壓器中引起偏移電流,這會(huì)降低該變壓器的電感。電感的這種減小將使數(shù)據(jù)傳輸特性發(fā)生劣化,而且,嚴(yán)重的時(shí)候還會(huì)導(dǎo)致很高的誤碼率(BER)或數(shù)據(jù)的完全丟失。早期報(bào)道認(rèn)為,從物理上看,不可能開發(fā)出能同時(shí)傳送較高電流并保持嚴(yán)格的千兆位以太網(wǎng)傳輸特性的數(shù)據(jù)磁性元件。不過,多個(gè)數(shù)據(jù)變壓器公司已經(jīng)證明,這在物理上是可能的。
3、分級(jí)機(jī)制
新的分級(jí)機(jī)制是需要仔細(xì)進(jìn)行工程設(shè)計(jì)的領(lǐng)域之一,該機(jī)制使供電設(shè)備(PSE)和受電設(shè)備能夠相互識(shí)別。有了這種相互識(shí)別能力,供電設(shè)備就可以恰當(dāng)?shù)叵?af(又稱為Type1硬件)和.at(Type2)受電設(shè)備供電,.af受電設(shè)備也可以由.at供電設(shè)備供電,而且.at受電設(shè)備能夠知道它是否能得到其較大負(fù)載所需的全部功率。每種組合都需要有明確定義和一致的工作規(guī)則,這樣才能保持被認(rèn)為是802.3標(biāo)準(zhǔn)支柱的互操作性。802.3at采用了更加詳盡的硬件分級(jí)機(jī)制和新的數(shù)據(jù)層機(jī)制,已經(jīng)實(shí)現(xiàn)了這種相互識(shí)別。
802.3at硬件分級(jí)被稱為“兩事件分級(jí)”(2-event classification),并涉及那些基本上重復(fù)兩次802.3af電壓探測(cè)的PSE。每次對(duì)PD的電壓探測(cè)都同時(shí)引起一個(gè)被吸收的電流脈沖(參見圖),該電流脈沖對(duì)應(yīng)一個(gè)特定的功率級(jí)。首先,PSE在數(shù)據(jù)或備用線上確定一個(gè)15.5V
至20.5V的電壓脈沖。PD以高達(dá)40mA的電流響應(yīng),告訴PSE它是4個(gè)功率級(jí)中的哪一個(gè)。雙脈沖是一個(gè)至PD的信號(hào),告訴PD所連接的PSE確實(shí)是一個(gè)大功率PSE,能夠提供802.3at規(guī)定的較高功率。802.3at PD以4級(jí)電流響應(yīng),告訴PSE它是一個(gè)大功率PD,需要29.5W功率。在802.3af中,Layer1分級(jí)方法是可選的方法,供PSE查詢PD,以確定PD的功率需求。在802.3at規(guī)范中,命令PSE執(zhí)行這種分級(jí)方法。
除了上述的硬件分級(jí)之外,PoE+任務(wù)組還定義了一個(gè)新的數(shù)據(jù)層分級(jí),稱為“鏈路層發(fā)現(xiàn)協(xié)議”(Link Layer Discovery Protocol,LLDP),用于PSE和PD之間的通信。一旦鏈路受電,PSE和PD將能夠采用LLDP來確定PD的功率需求。采用LLDP后,允許PSE重復(fù)查詢PD,以了解PD狀態(tài)及其功率需求。有了這個(gè)機(jī)制,就有可能實(shí)現(xiàn)動(dòng)態(tài)功率分配,PSE可以不斷向PD發(fā)布新級(jí)別的功率,PD也可以提出并在隨后放棄功率請(qǐng)求。隨著系統(tǒng)向更加環(huán)保的電源環(huán)境發(fā)展,這種新的動(dòng)態(tài)功率分配一定會(huì)成為一種重要功能。這種新的Layer2分級(jí)機(jī)制對(duì)PSE而言是可選的,但是要求PD實(shí)施。圖1顯示了PoE+中使用的分級(jí)方法。802.3at任務(wù)組仍在研究有關(guān)這部分標(biāo)準(zhǔn)的細(xì)節(jié),因此可以預(yù)期,隨著該任務(wù)組逐步完成對(duì)該通信協(xié)議的定義,還會(huì)出現(xiàn)一些變化。